Control DEVICES


- pH controller
- Dual time programmable output
- direct control of dosing pumps
- Solenoid for blowing, designed to give a signal to motor or pneumatic valve
- with a pH range of 0-14
- with 4-20 mA output
- With programmable alarm outputs
- 2 or 3 proportional output option
- LCD display screen
- IP65 protected


- pH controller
- Dual time programmable output
- direct control of dosing pumps
- Solenoid for blowing, designed to give a signal to motor or pneumatic valve
- with a pH range of 0-14
- with 4-20 mA output
- With programmable alarm outputs
- 2 or 3 proportional output option
- LCD display screen
- IP65 protected


- Conductivity controller
- Automatic tower / boiler blower
- Dual time programmable output
- 1 inhibitor dosage mode
- Dual-time biocide dosage mode
- direct control of dosing pumps
- 0-20000 μS measurement range
- 4-20mA output
- With programmable alarm outputs
- Solenoid, motorized, pneumatic valve control
- LCD display screen
- IP65 protected


- Conductivity controller
- Available for medium-sized boilers (according to ASME)
- 17,3 bar probable with 204 ° C
- Automatic boiler blower
- Dual time programmable output
- can control the dosage of 1 scale preventive dosing pump
- direct control of dosing pumps
- 0-20000 μS measurement range
- 4-20mA output
- With programmable alarm outputs
- Solenoid, pneumatic or motorized valve control
- LCD display screen
- IP65 protected


- pH measurement & Regulation
- Microprocessor digital pH controller
- Temperature measurement
- User friendly programming and set up menu
- 2 different set point options
- 2 Digital Proportional
- 2 On/Off
- Able to control
- Chemical tank level
- Flow rate in the probe holder
- Standby
- Three output relays
- Two On/Off voltage outputs (220V)
- Two Proportional outputs (pulses)
- One 0/4 ÷ 20 mA proportional output
- Wide variety of application options with adjustable acc.
- Different probe alternatives ranging to application


- ORP MEASUREMENT & REGULATION
- Microprocessor digital ORP controller
- Temperature measurement
- User friendly programming and set up menu
- Measurement range -1000mV-2000mV/temperature measurement
- 2 different set point options
- 2 Digital Proportional
- 2 On/Off
- Able to control
- Chemical tank level
- Flow rate in the probe holder
- Standby
- Three output relays
- Two On/Off voltage outputs (220V)
- Two Proportional outputs (pulses)
- One 0/4 ÷ 20 mA proportional output
- Wide variety of application options with adjustable acc.
- Different probe alternatives ranging to application


CONDUCTIVITY MEASUREMENT & REGULATION
Microprocessor digital conductivity controller Temperature measurement
User friendly programming and set up menu
Measurement range 0-300000µS
2 different set point options
2 Digital Proportional
2 On/Off
Able to control
Chemical tank level
Flow rate in the probe holder
Standby
Three output relays
Two On/Off voltage outputs (220V)
Two Proportional outputs (pulses)
One 0/4 ÷ 20 mA proportional output
Wide variety of application options with adjustable acc.
Different probe alternatives ranging to application

DISINFECTION MEASUREMENT & REGULATION
Microprocessor digital disinfection controller
Temperature measurement
User friendly programming and set up menu
Able to measure free chlorine,total chlorine,chlorine dioxide,hydrogen peroxide
ozone,peracetic acid, bromine
Wide range of different measurement availability
With different probe and probe holders options( amperometric,batch,off-line,submersible)
2 different set point options
2 Digital Proportional
2 On/Off
Able to control
Chemical tank level
Flow rate in the probe holder
Standby
Three output relays
Two On/Off voltage outputs (220V)
Two Proportional outputs (pulses)
One 0/4 ÷ 20 mA proportional output
Wide variety of application options with adjustable acc.
Different probe alternatives ranging to application


DISSOLVED OXYGEN MEASUREMENT & REGULATION
Microprocessor digital dissolved oxygen controller
Temperature measurement
User friendly programming and set up menu
Wide range of different measurement availability:
With different probe and probe holders options( amperometric,batch,off-line,submersible)
2 different set point options
2 Digital Proportional
2 On/Off
Able to control
Chemical tank level
Flow rate in the probe holder
Standby
Three output relays
Two On/Off voltage outputs (220V)
Two Proportional outputs (pulses)
One 0/4 ÷ 20 mA proportional output
Wide variety of application options with adjustable acc.
Different probe alternatives ranging to application


Remote control device
Able to control 32 different plants in the same time
Able to send SMS to mobiles
Able to send graphics in Ms Applications


Microprocessor pH / ORP or pH / Conductivity Meter Temperature Compenent
User friendly menu
4 different tank level indicator
Two flowmeter inputu to measure evaporation losses
Time-dependent or continuous bluff automation
4 pump out
0-20,000μS measurement range
Temperature measurement option in ° C -F °
CE certified